Verify a reference lab's CLIA certificate
Under 42 CFR 493.1242(c), a lab may refer specimens only to a CLIA-certified laboratory or one meeting equivalent requirements. Before sending specimens, look up the reference lab's CLIA number, confirm its certificate type covers the tests, check the expiration date, and keep a dated copy of the verification on file.
Verify a reference lab's CLIA
A CLIA number or ZIP code finds its state automatically.
Data: CMS Provider of Services file, active labs as of July 1, 2026, cleaned by Sound Lab Consultants. For official verification or to print a certificate, confirm on CMS QCOR.
Referral lab checklist
- CLIA number and testing address match the lab you send to
- Certificate type covers the complexity of the tests
- Certificate is current; calendar the expiration date
- State license where your state requires one for out-of-state labs
- Signed agreement and written specimen instructions
- Dated verification saved in your records, rechecked yearly
Each result shows the certificate type and expiration date. Confirm any lab on CMS QCOR before relying on it.
Regulations behind this
| Regulation | What it covers |
|---|---|
| 42 CFR § 493.1242Standard: Specimen submission, handling, and referral | Specimen submission, handling and referral |
Full text of the regulations
Tap a regulation to read the complete official text.
§ 493.1242 Standard: Specimen submission, handling, and referral.
(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable:
(1) Patient preparation.
(2) Specimen collection.
(3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source.
(4) Specimen storage and preservation.
(5) Conditions for specimen transportation.
(6) Specimen processing.
(7) Specimen acceptability and rejection.
(8) Specimen referral.
(b) The laboratory must document the date and time it receives a specimen.
(c) The laboratory must refer a specimen for testing only to a CLIA-certified laboratory or a laboratory meeting equivalent requirements as determined by CMS.
(d) If the laboratory accepts a referral specimen, written instructions must be available to the laboratory's clients and must include, as appropriate, the information specified in paragraphs (a)(1) through (a)(7) of this section.
Official text from the Electronic Code of Federal Regulations (eCFR), current as of November 24, 2026.
Frequently asked questions
How often should I re-verify a reference lab?
At least at each certificate renewal, and whenever the lab changes name, owner or address. Many labs recheck annually.